聯(lián)系我時,請告知來自 機床商務(wù)網(wǎng)DELTA TM3PD pneumatic modules represent the blend of traditional leak test equipment and are the best solution to integrate a reliable and compact testing station into your automated system.
PERFORMANCES
The absence of buttons and displays has allowed to reduce overall dimensions, so as to ensure their placement in any type of system, as close as possible to the component under test, minimizing unnecessary volumes and increasing the speed and sensitivity of the test.
DELTA TM3PD pneumatic modules can be connected and controlled by any PLC.
CONNECTIVITY
? Software to collect and manage the data of the tests
? Viewing and management of several testing stations
? Parameter programming and SPC analysis of test data
? Virtual Instrument per LabVIEW™ di National Instruments available at request.
優(yōu)勢Leak test up to 30 bar
Resolution up to 0.1 Pa, differential
Full scale from 10 to 50 mbar
Fully integrated pneumatics and electronics
Test time reduced
Ease of use and installation
Digital interface for PLC
Communication Interfaces RS485 and USB
Up to 300 test tables
Power Supply | 24 Vdc - 1 A max |
Compressed Air Line | Dry, non-condensing, 5-micron filtered, and oil-free air, compliant with ISO8573-1, 6x4 mm hose fitting 4x2.5 / 6x4 / 8x6 mm Pilot pressure compatible with the instrument full scale |
Sensor Calibration | Remote control software procedure with external sample instruments |
A/D Converter | 2x24 bits |
Pressure Regulator | External (option) |
Indicators | 4 LEDs: two yellow (test phases), green (passed), red (failed) |
Test Counter | PASSED and FAILED totals, resettable to zero |
Clock | Clock Date and time, with supercap, 7 days back up max |
Programmable parameters | Up to 300 testing tables, general testing parameters |
PLC Connection | 2 Photocoupled inputs: START / RESET 4 Photocoupled outputs: TEST RUNNING, PASSED, FAILED, ALARM 3 Additional digital inputs (-I3) |
Data interfaces | RS485 and USB communication interfaces with Modbus protocol |
Staubli® Connector | For leak masters available on external connection |
Housing | Unpainted anodized aluminium |