詳細(xì)介紹
Specification
For further information and the best possible application and performance support please contact Renishaw or visit
/rmp40
Note 1 Performance specification is tested at a standard test velocity of 480 mm/min (18.9 in/min) with a 50 mm stylus. Significantly higher velocity is possible
depending on application requirements.
Note 2 Trigger force, which is critical in some applications, is the force exerted on the component by the stylus when the probe triggers. The maximum force applied will occur after the trigger point (overtravel). The force value depends on related variables including measuring speed and machine deceleration.
Note 3 These are the factory settings, manual adjustment is not possible.
Principal application Workpiece inspection and job set-up on machining centres and multi-tasking machines.
Transmission type Frequency hopping spread spectrum (FHSS) radio
Radio frequency 2400 MHz to 2483.5 MHz
Radio approval regions China, Europe (all countries within the European Union), Japan and USA.
For details about other regions, please contact Renishaw.
Compatible interfaces RMI and RMI-Q
Operating range Up to 15 m (49.2 ft)
Recommended styli Ceramic, lengths 50 mm (1.97 in) to 150 mm (5.91 in)
Weight without shank (including batteries) 250 g (8.81 oz)
Switch-on/switch-off options Radio on Radio off or timer off
Spin on Spin off or timer off
Battery life(2 × ½ AA 3.6 Vlithium-thionyl chloride)
Standby life 290 days maximum, dependent on switch-on/switch-off option.
Continuous use 450 hours maximum, dependent on switch-on/switch-off option.
Sense directions ±X, ±Y, +Z
Unidirectional repeatability 1.00 μm (40 μin) 2s (see note 1)
Stylus trigger force (see notes 2 and 3)
XY low force
XY high force
+Z direction
0.50 N, 51 gf (1.80 ozf)
0.90 N, 92 gf (3.24 ozf)
5.85 N, 597 gf (21.04 ozf)
Sealing IPX8 (EN/IEC 60529)
Operating temperature +5 °C to +55 °C (+41 °F to +131 °F)