Nikon Ti2-E倒立電動(dòng)顯微鏡
![](https://img69.jc35.com/99c876c5d9ae48d91459e186c83ad36dddaab10b6ed6005c5b61ab4a95de041c5ae2adcac10820f0.jpg)
Groundbreaking FOV開創(chuàng)性大視野設(shè)計(jì):
![](https://img68.jc35.com/99c876c5d9ae48d91459e186c83ad36d77b8a346f3e30efbed465f052966822dd0a52b369b302716.png)
大視野白光光源:高能量LEDs光源加上fly-eye lens複眼均勻片,提供勻稱且大範(fàn)圍的照明。
![]() | ![]() |
大視野螢光光源:配置石英複眼鏡片(Quartz fly-eye lens),涵蓋光譜頻寬至UV波段,並設(shè)計(jì)大尺寸螢光濾片組。
![]() | ![]() |
大尺寸觀察光學(xué)元件:觀察光路與照相光路均加大至25mm,可截取比傳統(tǒng)約2倍大的範(fàn)圍。
![]() | ![]() |
大視野物鏡:
![](https://img71.jc35.com/99c876c5d9ae48d91459e186c83ad36d093e35e480e79a8a736a31ccb943865ee0592e0070b5f47c.jpg)
Unsurpassed Nikon optics的光學(xué)鏡片:
Apodized Phase Contrast:相位差
![](https://img71.jc35.com/99c876c5d9ae48d91459e186c83ad36dc6c8ccfe3c2a3617fb8df484b889c881e9f8d00865ea7850.jpg)
External Phase Contrast (Ti2-E):外掛式相位差
![](https://img71.jc35.com/99c876c5d9ae48d91459e186c83ad36db653d8a9913d7534b2646976b69bc3adf5fc8fdee97b0683.jpg)
NAMC (Nikon Advanced Modulation Contrast):
![](https://img67.jc35.com/99c876c5d9ae48d91459e186c83ad36d3775c1230a0f7f14665583b293b7334d81087030a0c4cdb7.jpg)
Auto Correction Collar (Ti2-E):自動(dòng)蓋玻片校正環(huán)
![](https://img67.jc35.com/99c876c5d9ae48d91459e186c83ad36d43166f6ebb8f0a3d2f69b707c4eca8978b9d597c35b59d14.jpg)
λS 系列物鏡:運(yùn)用Nikon的奈米晶粒塗層技術(shù),有效增加光線的穿透率。
![](https://img64.jc35.com/99c876c5d9ae48d91459e186c83ad36d2bf7d6c0033803ad706eabbc3d96b335c729ba28b489358b.jpg)
Focus perfected對焦:
超高穩(wěn)定性(Ti2-E):重新設(shè)計(jì)Z-drive與PFS對焦系統(tǒng),即使使用staged-up架高組件,仍能維持靠近鼻輪。
![](https://img68.jc35.com/99c876c5d9ae48d91459e186c83ad36d210d04992d36a6a6da5d4e3647b64fe3b165e06663aeb5d1.jpg)
第四代Nikon Perfect Focus System (Ti2-E):防漂移對焦裝置,可抵抗溫度變化與機(jī)械震動(dòng),即使加藥動(dòng)作與多點(diǎn)移動(dòng)也能維持焦距
![](https://img71.jc35.com/99c876c5d9ae48d91459e186c83ad36dc380deaad602e04cfe8640e0bb5a3f90f66a83531e5d8bff.jpg)
![](https://img76.jc35.com/99c876c5d9ae48d91459e186c83ad36d92f90f73267431bc766682c27ae98462df5fa01b7d2963dc.jpg)
![](https://img71.jc35.com/99c876c5d9ae48d91459e186c83ad36dc9ee16fb4cdcad2ea385226163196545587b18f707781a96.jpg)
Intelligent Assist Guide智慧輔助導(dǎo)覽:
![](https://img71.jc35.com/99c876c5d9ae48d91459e186c83ad36d2d4bfb0cbc5b62c21f30596cf173bcebc547f35217b0bb2f.jpg)
持續(xù)顯示顯微鏡狀態(tài) (Ti2-E/ A)
![](https://img64.jc35.com/99c876c5d9ae48d91459e186c83ad36d1ec2b0cd39ca1f42375e7e8ce4861f87d79b85f449c20eda.jpg)
導(dǎo)引式操作流程 (Ti2-E/ A)
![](https://img70.jc35.com/99c876c5d9ae48d91459e186c83ad36dcf4569903e3f30eae1a5edbf2dd53922b9d202ce14d98686.jpg)
● Automatically Detect Errors自動(dòng)錯(cuò)誤偵測 (Ti2-E/ A)
![](https://img68.jc35.com/99c876c5d9ae48d91459e186c83ad36dd29bd65122e3dffbd11357c28c05ce8e4480f9ec2de90708.jpg)
Intuitive operation直觀操作介面:
直覺式操作介面
![](https://img62.jc35.com/99c876c5d9ae48d91459e186c83ad36d1410259ff62708e9457537df60f2e3ac61cc1fa8bad70ad5.png)
- Shuttle Switch (Ti2-E)飛梭切換鈕 (Ti2-E)
- Programmable Function Button (Ti2-E/A)
- Focusing Knob (Ti2-E)
以搖桿或平板直覺式控制
![](https://img62.jc35.com/99c876c5d9ae48d91459e186c83ad36d28c43ef4a1c88cb80e3664707e0c03d12d42bbcb0d217f1f.jpg)
![](https://img68.jc35.com/99c876c5d9ae48d91459e186c83ad36dbb3dcdbe6c0b64a2f90e1636c782825c09d5f93f54b41245.jpg)
Nikon Ti2-E specifications規(guī)格表:
ECLIPSE Ti2-E / Ti2-E/B*1 | ||
Main body | Optical system | Infinity-corrected CFI60 |
Field number*2 | 22 with C-mount, 25 with F-mount | |
Intermediate Magnification switching | Manual switching of 1.0x/1.5x (exchangeable from 1.5x to 2.0x) | |
Status detection | ||
Bertrand lens | Manual in/out, and manual focus, Status detection | |
Output port | 4 Motorized positions Eyepiece 99%, left 99%, right 99%,eyepiece 20%/left 80% (Ti2-E/B: bottom 99%) | |
Can add ports by use of back port unit and/or choice of tube base unit*3 | ||
Focusing unit | Motorized drive, Coarse/fine focus changeover, 10mm stroke Minimum increments: 0.01um, 0.02um (with encoder control) | |
Stage up | Available *4 | |
Tube body | Binocular tube | Binocular S tube TC-T-TS (field number 22), Ergonomic ER tube TC-T-ER (field number 22) |
Motorized eyepiece tube base unit for external PH (TI2-T-BP-E) | Camera port (field number 16), Motorized PH turret with 4 motorized positions | |
Assist eyepiece tube base unit (TI2-T-BA) | Assist camera (field number 22), Status detection | |
Eyepiece tube base unit with port (TI2-T-BC) | Camera port (field number 16) | |
Transmitted illumination | Pillar for transmitted illumination (TI2-D-PD) | Condenser vertical stroke: 66mm, Backward tilting up to 25 degrees, With field diagram and refocusing mechanism 2 filter slot positions (4 filter position option is also available with Filter Slider for transmitted illumination (TI2-D-SF) |
LED Lamphouse for dia illumination (TI2-D-LHLED) | High power LED | |
Precentered Lamphouse (D-LH/LC) | 100W halogen bulb (pre-centered) | |
Condenser | Motorized condenser turret (TI2-C-TC-E) | 7 motorized positions (ψ37mm x4, ψ39mm x3), LWD/ELWD/CLWD/NAMC condenser lenses are supported |
Intelligent condenser turret (TI2-C-TC-I) | 7 manual positions (ψ37mm x4, ψ39mm x3), Status detection, LWD/ELWD/CLWD/NAMC condenser lenses are supported | |
Condenser turret (TC-C-TC) | 7 manual positions (ψ37mm x4, ψ39mm x3), LWD/ELWD/CLWD/NAMC condenser lenses are supported | |
ELWD-S condenser turret (TE-C) | 4 manual positions, With ELWD condenser lens (NA0.3 / OD65) | |
HNA condenser slider (TI2-C-SCH) | 2 manual positions (ψ37mm x1, ψ39mm x1), HNA dry lens/ HNA oil lens are supported | |
Condenser lens | LWD (W.D.=30mm, NA=0.52), ELWD (W.D.=75mm, NA=0.3), CLWD (W.D.=13mm, NA=0.72), HNA dry (W.D.=5mm, NA=0.85), HNA oil (W.D.=1.9mm, NA=1.3), NAMC (W.D.=44mm, NA=0.4) | |
Stage | Motorized stage (TI2-S-SE-E, TI2-S-SS-E) | Stroke X:±57mm, Stroke Y: ±36.5mm, Max drive speed: approx. 25mm/sec, Magnetic sample holder |
Stage (TC-S-SR, TC-S-SRF) | Stroke X:±57mm, Stroke Y: ±36.5mm, Adjustable stroke range (3 levels) with adjusting pin, Long/middle/short handle options available | |
Gliding stage (TC-S-GS) | Strokeψ20mm | |
Nosepiece | Perfect Focus Unit with motorized nosepiece for Auto Correction Collar (TI2-N-NDA-P) | 5 motorized positions, Simple waterproof structure |
Motorized DIC sextuple nosepiece (TI2-N-ND-E) Perfect Focus Unit with motorized nosepiece (TI2-N-ND-P) Perfect Focus Unit with motorized nosepiece for MP (TI2-N-NDM-P) | 6 motorized positions, Simple waterproof structure | |
Intelligent DIC sextuple nosepiece (TI2-N-ND-I) | 6 manual positions, Status detection, Simple waterproof structure | |
Sextuple nosepiece (TI2-N-N), DIC sextuple nosepiece (TI2-N-ND) | 6 manual positions, Simple waterproof structure | |
Epi-filter turret | Motorized epi filter turret (TI2-F-FLT-E, TI2-F-FLTH-E) | 6 motorized positions, Motorized shutter |
Intelligent epi filter turret (TI2-F-FLT-I) | 6 manual positions, Manual shutter, Status detection*5 | |
Filter wheel/ shutter | Motorized BA filter wheel (TI2-P-FWB-E) | 7 motorized positions, High speed mode: 50ms, Low vibration mode: 100ms (movement time between adjacent positions) |
Motorized shutter (NI-SH-E)*6 | 12ms to open/close | |
Epi-fluorescence attachment | EPI-FL module (TI2-LA-FL), EPI-FL module for large FOV (TI2-LA-FLL) | Supports fiber illuminator; includes 2-position filter slider and aperture diaphragm |
Simple EPI-FL attachment (TI2-F-FLS) | Supports both fiber illuminator and lamp house; includes 3-position filter slider | |
Field stop slider | Circular (TI2-F-FSC), rectangular (TI2-F-FSR), square (Ti2-F-FSS) aperture options | |
Control unit | Controller, display device | Stage joystick (TI2-S-JS), Tablet |
Controller for TI2-E (TI2-CTRE) | USB/LAN interface, I/O function | |
Operating environmental | Temperature: 0℃-40℃, Humidity: 60% RH max. (at +40℃, no condensation), Indoor use only | |
*1 Motorized model with a bottom port *2 Limitations apply based on objective and filter cube choice, stage-up configuration, and illumination module, etc. *3 Tube base units with a port cannot be used with Ti2-A *4 Stage up kit is required. Please contact Nikon. *5 Status detection cannot be used when attached to the Ti2-U *6 NI-SH-CON Controller for Motorized Shutter is required for use with the Ti2-A/Ti2-U |