The OP SERIES are designed according to specifications dedicated to identified applications
ROBOT Arm compatible with Long Working Distance and Extended Measuring Range
More than 10 references are optimized in Photometric Efficiency, Working Distance, Slope Angle Acceptance to measure Contactless Roughness, Multilayer Thickness, Curved Surfaces…
Usually implemented in OEM machine to work in industrial environment on-line, OP SERIE is the ideal compromised between Flexibility, Mechanical & Optical constraints, Performances & Prices.
Ideal for specific and dedicated application to acquire signal on-Line as on Dark Bottle Thickness Measurement.
Customized and Adaptable to the widest range of applications, composed of Passive Components, OP SERIES are robust and reliable, suitable for use with every STIL MARPOSS Controllers as ZENITH, CCS SERIES ; LIGHTMASTER or IRIX
優(yōu)勢- Exceptional Long Working Distance until more than half a meter
- Ideal to implement a specific Optical Path in respect with mechanical constraints
- Dedicated to industrial environment, independent from Ambiant Light
- High Axial resolution : From Nanometer to Micrometer scale
- High Photometric Efficiency
- High signal to noise ratio
- Works on all types of samples
- Steep slope compatibility thanks to High Numerical Aperture
- Coaxial : no Shadow Effect
- ? Speckle ? free
On CCS SERIES
Part number |
| CHR-900-N4 | CHR-900-N1 | C102-000-N3 | PPS06-000-N1 | CR60-100-N1 | QUIN-100-N1 | CHR2-822-N2 |
Model | unit | OP300VM | OP300VM-90° | OP1000 | CL4-LWD | OP6000 | OP8000 | OP10000 |
Measuring range | µm | 220 | 220 | 1000 | 4000 | 6000 | 8000 | 10000 |
Working distance | mm | 5 | 4,4 | 23,9 | 40 | 28 | 39 | 66,9 |
Numerical aperture |
| 0,5 | 0,5 | 0,45 | 0,36 | 0,39 | 0,295 | 0,2 |
Max. sample slope | ° | 25 | 25 | 24 | 21 | 22 | 16 | 11 |
Protective window |
| no | no | yes | yes | no | yes | yes |
Axial or folded model |
| axial | 90° folded | axial | axial | axial | axial | axial |
Spot size | µm | 6,4 | 6,4 | 4,4 | 8,6 | 12,5 | 33 | 50 |
Lateral resolution | µm | 3,2 | 3,2 | 2,2 | 4,3 | 6,25 | 16,5 | 25 |
Photometric efficiency |
| 34 | 19 | 10 | 25 | 43 | 133 | 138 |
Static noise | nm | 12 | 12 | 30 | 60 | 100 | 160 | 280 |
Axial resolution | µm | 0,072 | 0,072 | 0,18 | 0,36 | 0,6 | 0,96 | 1,68 |
Max. linearity error | nm | 40 | 40 | 150 | 200 | 300 | 350 | 510 |
Min. measurable thickness | µm | 25 | 25 | 25 | 110 | 200 | 300 | 425 |
Length | mm | 127 | 128 | 254,1 | 167,4 | 205,5 | 139 | 189 |
Diameter | mm | 15 | 15 | 50 | 50 | 60 | 40 | 50 |
Weight | g | 27 | 39 | 753 | 470 | 760 | 365 | 525 |
Part number |
| CHR2-820-N2 | PPS001-100-N2 | C24SC-100-N1 | PPS05-100-N1 | PNCO-100-N3 | PNCO-100-N5 | PNCO-100-N4 | NCTP-100-N1 |
Model | unit | OP10000-90° | OP12000 | OP30000 | OP35000 | OP42000 | OP60000 | OP100000 | NCTP |
Measuring range | µm | 10000 | 12000 | 30000 | 35000 | 42000 | 60000 | 100000 | 20000 |
Working distance | mm | 66,9 | 46 | 220 | 62 | 530 | 650 | 451 | 54,5 |
Numerical aperture |
| 0,2 | 0,25 | 0,095 | 0,33 | 0,052 | 0,04 | 0,08 | 0,35/0,17 |
Max. sample slope | ° | 11 | 14 | 5 | 17 | 2,5 | 2 | 5 | 18/9 |
Protective window |
| yes | no | no | no | no | no | no | yes |
Axial or folded model |
| 90° folded | axial | axial | axial | axial | axial | axial | axial |
Spot size | µm | 50 | 32,5 | 96 | 26 | 106 | 142 | 110 | 30 |
Lateral resolution | µm | 25 | 14 | 48 | 13 | 53 | 73 | 55 | 15 |
Photometric efficiency |
| 138 | 100 | 75 | 30 | 90 | 90 | >150 | 73 |
Static noise | nm | 280 | 225 | 750 | 600 | 6000 | 18000 | 5000 | 350 |
Axial resolution | µm | 1,68 | 1,35 | 4,5 | 3,6 | 36 | 108 | 30 | 2,1 |
Max. linearity error | nm | 510 | 400 | 1500 | 1650 | 30000 | 150000 | 16000 | 1400 |
Min. measurable thickness | µm | 425 | 550 | 2000 | 1200 | 2500 | 6000 | 2500 | 500 |
Length | mm | 152 | 58,3 | 168 | 300,3 | 327 | 305,5 | 348,9 | 210 |
Diameter | mm | 50 | 36 | 59 | 80 | 85 | 85 | 120 | 80/35 |
Weight | g | 674 | 130 | 405 | 2200 | 1700 | 1600 | 4200 | 1025 |